https://ttsui.futurismdemo.com/Media/Images/500X644//Rosemount_40942.png

Rosemount 3051S Series Coplanar Pressure Transmitter

The Rosemount 30151S CoplanarTM pressure transmitter can be easily integrated with primary elements, manifolds, and sealing solutions. The transmitter is equipped with CoplanarTM that ensures accurate measurement of gage, differential, and absolute pressures. The integrated SuperModuleTM platform helps resist line pressure, as well as overpressure effects, and provides reliable performance in adverse conditions.

Availability: In stock
Request A Quote

Specification

Rosemount 3051S Series Coplanar Pressure Transmitter

Accuracy

3051S_CD/CG, Ranges 2-4:

Classic: +0.035% of span, For spans less than 10:1: ±[0.015 + 0.005(URL / Span)]% of span

Ultra: +0.025% of span, For spans less than 10:1: ±[0.005 + 0.0035(URL / Span)]% of span

Ultra for Flow(3051S_CD Only, Ranges 2-3): +0.04% of reading up to 8:1 DP turndown from URL, or ±[0.04 + 0.0023(URL / Reading)]% of reading to 200:1 DP turndown from URL

3051S_CD/CG, Range 5:

Classic: +0.065% of span, For spans less than 10:1, ±[0.015 + 0.005(URL / Span)]% of span

Ultra: +0.05% of span, For spans less than 10:1, ±[0.005 + 0.0045(URL / Span)]% of span

3051S_CD/CG, Range 1:

Classic: +0.10% of span, For spans less than 15:1, ±[0.025 + 0.005(URL / Span)]% of span

Ultra: +0.09% of span, For spans less than 15:1, ±[0.015 + 0.005(URL / Span)]% of span

3051S_CD, Range 0:

Classic: +0.10% of span, For spans less than 2:1: ±0.05% of URL

Ultra: +0.09% of span, For spans less than 2:1: ±0.045% of URL

3051S_CA, Ranges 1-4:

Classic: +0.035% of span, For spans less than 10:1: ±[0.0065(URL / Span)]% of span

Ultra: +0.025% of span, For spans less than 10:1: ±[0.004(URL / Span)]% of span

3051S_CA, Range 0:

Classic: +0.075% of span, For spans less than 5:1: ±[0.025 + 0.01(URL / Span)]% of span

Ultra: +0.075% of span, For spans less than 5:1: ±[0.025 + 0.01(URL / Span)]% of span

Output

Two-wire 4-20 mA is user-selectable for linear or square root output. Digital signal based on HART

Range

051S_CA: 0-0.167 to 0-4000 psia

3051S_CD: 0-0.01 in H2O to 0-2000 psid

3051S_CG: 0-8.3 in H2O to 2000 psig

Power

3051S: 10.5-42.4 V dc with no load

3051S with Advanced HART Diagnostic Suite: 12-42.4 V dc with no load

Process Wetted Material

316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L SST

Materials

Sensor Wetted Parts: 316L SST, Hastelloy, Monel, Tantalum, Gold-plated SS, Gold-plated Monel

Sensor Fill Fluid: Silicone, Inert (Halocarbon)

Coplanar and Traditional Flanges and Adapters: Cadmium and Nickel-plated CS, 316 SST, Hastelloy, Monel

Process Flange

Carbon Steel, SST

Features

Our Brands

>