https://ttsui.futurismdemo.com/Media/Images/500X644//PR Electronics_40995.png

2-Wire Temperature Transmitter with HART Protocol - 5335D

Application:-

  • Linearized temperature measurement with Pt100...Pt1000, Ni100...Ni1000, or TC sensor.
  • Difference or average temperature measurement of 2 resistance or TC sensors
  • Conversion of linear resistance variation to a standard analog current signal, for instance from valves or Ohmic level sensors
  • Amplification of a bipolar mV signal to a standard 4...20 mA current signal.
  • Connection of up to 15 transmitters to a digital 2-wire signal with HART communication

Technical characteristics:-
  • Within a few seconds the user can program PR5335D to measure temperatures within all ranges defined by the norms.
  • The RTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.
  • The 5335D has been designed according to strict safety requirements and is therefore suitable for application in SIL installations.
  • Continuous check of vital stored data for safety reasons
  • Sensor error detection according to the guidelines in NAMUR NE89.

Mounting / installation:-
  • For DIN form B sensor head mounting

Availability: In stock
Request A Quote

Specification

2-Wire Temperature Transmitter with HART Protocol - 5335D

Environmental Conditions:-

Operating temperature:

-40°C to +85°C

Calibration temperature:

20...28°C

Relative humidity:

<95% RH (non-cond.)

Protection degree (encl./terminal):

IP68 / IP00

Mechanical specifications:-

Dimensions:

Ø 44 x 20.2 mm

Weight approx:

50 g

Wire size:

1 x 1.5 mm2 stranded wire

Screw terminal torque:

0.4 Nm

Vibration:

IEC 60068-2-6

2...25 Hz:

±1.6 mm

25...100 Hz:

±4 g

Common specifications:-

Supply:-

Supply voltage: 8.0...30 VDC

Isolation voltage

Isolation voltage, test / working: 1.5 kVAC / 50 VAC

Response time:-

Response time (programmable): 1...60 s

Warm-up time: 30s.

Start-up time: <2.75 s

Programming: Loop Link & HART

Signal / noise ratio: Min. 60 dB

Accuracy: Better than 0.05% of selected range

Signal dynamics, input: 22 bit

Signal dynamics, output: 16 bit

Effect of supply voltage change: <0.005% of span/VDC

EMC immunity influence: < ±0.1% of span

Extended EMC immunity: NAMUR

NE21, A criterion, burst: <±1% of span

Input specifications:-

Common input specifications:0

Max. offset: 50% of selected max. value

RTD Input:-

RTD type: Pt100, Ni100, lin. R

Cable resistance per wire: 5 O (up to 50 O per wire is possible with reduced measurement accuracy)

Effect of sensor cable resistance (3-/4-wire): <0.002 O / O

Sensor current: Nom. 0.2 mA

Sensor error detection:Yes

TC Input:-

Thermocouple type: B, E, J, K, L, N, R, S, T, U, W3, W5

Basic accuracy, e.g. TC K: = ±0.25°C

Cold junction compensation (CJC): <±1.0°C

Sensor error detection: Yes

Sensor error current: When detecting / else: Nom. 33 µA / 0 µA

Voltage input:-

Measurement range: 800...+800 mV

Min. measurement range (span): 2.5 mV

Input resistance: 10 MO

Output specifications:-

Current output:-

Signal range: 4…20 mA

Min. signal range: 16 mA

Load (@ current output): =(Vsupply - 8) / 0.023 [O]

Load stability: =0.01% of span / 100 O

Sensor error indication: Programmable 3.5…23 mA

NAMUR NE43 Upscale/Downscale: 23 mA / 3.5 mA

of span: = of the presently selected range

I.S. / Ex marking:-

ATEX: II 1 G Ex ia IIC T6...T4 Ga, II 2 D Ex ia IIIC Db, I M1 Ex ia I Ma

< IECEx: Ex ia IIC T6...T4 Ga, Ex ia IIIC Db, Ex ia I Ma

FM, US: Cl. I, Div. 1, Gp. A, B, C, D T4/T6; Cl. I Zone 0, AEx ia IIC T4/T6; Cl. 1, Div. 2, Gp. A, B, C, D, T4/T6

CSA: Cl. I, Div. 1, Gp. A, B, C, D Ex ia IIC, Ga

INMETRO: Ex ia IIC T6...T4 Ga, Ex ia IIIC Da, Ex ia I Ma

Observed authority requirements:-

EMC: 2014/30/EU

ATEX: 2014/34/EU

RoHS: 2011/65/EU

EAC: TR-CU 020/2011

EAC Ex: TR-CU 012/2011

Approvals:-

ATEX: DEKRA 20ATEX0108X

IECEx: DEK 20.0063X

CSA: 1125003

c FM us: FM17US0013X

INMETRO: DEKRA 18.0002X

DNV Marine: TAA0000101

EAC Ex: RU C-DK.HA65.B.00355/19

SIL: Hardware assessed for use in SIL applications

Resources

Technical Data-Sheet

2-Wire Temperature Transmitter with HART Protocol - 5335D

PR ELECTRONICS 5335D_18967_US.pdf

download-icon

Technical Data-Sheet

2-Wire Temperature Transmitter with HART Protocol - 5335D

PR ELECTRONICS 5335v120_MANUAL.pdf

download-icon

Technical Data-Sheet

2-Wire Temperature Transmitter with HART Protocol - 5335D

PR ELECTRONICS 5335D_18967_US.pdf

download-icon

Technical Data-Sheet

2-Wire Temperature Transmitter with HART Protocol - 5335D

PR ELECTRONICS 5335v120_MANUAL.pdf

download-icon

Our Brands

>