https://ttsui.futurismdemo.com/Media/Images/500X644//1 (7).jpg

Smart Temperature Transmitter LI-24ALW

The temperature transmitter LI-24ALW is applicable to converting resistance of temperature or voltage of thermocouple sensor to standard current signal 4-20mA. The transmitter has two separate channels enabling measurement of temperature difference, averange, averange with redundancy, max. or min. temperature. Transmitter has compensation of ambient temparature influence and compensation of thermocouple cold junction using internal/external (Pt100) sensor or constant temperature. Most of parameters such as: sensor type, measuring range, current alarm signal when electric circuit is broken, output characteristic correction, user characteristic (60 points) are programmed using PC with HART/USB converter and RAPORT 2 configuration software. Upon request the temperature transmitter parameters like measuring range, type of sensor can be set. Their values are printed on label. Transmitter LI-24/ALW is designed for field use. LI-24ALW can be used with temprature sensors mounted directly in transmitter’s casing or with external sensors connected with cable.

  • Output signal 4…20mA with Hart protocol
  • Galvanic insulation (In, Out)
  • Programmable sensor type
  • Programmable measuring range
  • Thermoresistance line compensation
  • Compensation of thermocouple cold junction
  • Autodiagnostic system
  • Intrinsic safety certificate (ATEX, IECEx)
  • Explosion proof certificate (ATEX, IECEx
  • Safety version SIL2/SIL3

Availability: In stock
Request A Quote

Specification

Smart Temperature Transmitter LI-24ALW

Input signal:-

Resistance: Pt100,Ni100

Voltage: K, J,S,B,N,T, R, E

Limit process:-

-10mV< E<100mV or -100mV< E<1000mV

0O< R<400O or 0O< R<2000O

Min. measuring range:-

10mV or 10O or 10K

Output signal:-

4- 20 mA + Hart

Power supply:-

13,5*…55 VDC

Exia: 13,5*…30 VDC

Exd: 13,5*…45 VDC

Safety, Safety Exd: 12,5…36 VDC

Safety Exia: 12,5…30 VDC

(*- with display illumination switched on +3V, display backlight can be switched on only during production)

Max. wires resistance:-

500O

Alarm signal:-

3,75mA / 21,5mA (NORMAL) or 3,6 mA / 21 mA (NAMUR NE89) or setting by user

Galvanic insulation:-

Optoelectrical

Sensor current:-

0,42mA

Safety: 0,25mA

Accuracy:-

acc. to below table

Time constant:-

0,3s

Additional electronic damping:-

0..30s

Ambient temperature:-

40…+176°F

Exia: -40…+176°F

Exd: -40…+167°F

Safety: -40…+185°F

Safety Exia, Safety Exd: -40…+167°F